Therefore the same procedures used for the design of adsorption columns may be used for ion exchange columns.
Ion exchange resin column design.
With the exception of the resin.
The ion exchangers used in this research project were i clinoptilolite a naturally occurring zeolite and ii a resin in h form with functional group sulfonic acid lewatit s2568h.
1 2 minutes column height.
4 each with a capacity of 120m3 h surface loading.
The hardness ions ca and mg move into the resin beads and each of these divalent.
The optimum column diameter must be a balance between the resin bed height the ratio of resin height to diameter h d and the linear velocity.
Continuous ion exchangers consist of two columns in parallel.
How to design an ion exchange resin system.
Goro nickel cobalt project in new.
A demineralizer system consists of one or more ion exchange resin columns which include a strong acid cation unit and a strong base anion unit.
Based on the experiment results and calculation the ion exchange is design as follows.
Ion exchange process for control of iron in copper electrolytes 1.
For example metal contaminants are.
Because it is lighter the weak acid resin remains on top.
Column size most industrial ion exchange columns have a diameter between 0 5 and 3 2 m.
Only a few general recommendations to ensure that an ion exchange system is designed economically and to achieve good performance and a simple but detailed example.
Usage examples continuous ion exchangers are used when it is imperative that product be continually generated.
Ion exchange takes place in one column while the resin in the second column is being regenerated resulting in continuous operation.
10 days material cost of resin per m3 water produced.
One variation of the standard design uses a layer of weak acid resin on top of strong acid cation resin.
The contacting techniques are almost identical.
The aim of the work described in this report was to design an ion exchange column for the removal of ammonium ions from ro permeate.
The recovered zinc is eluted with pure water and transferred intermittently to be treated by further refining 2.
O the scale up approach o the kinetic approach.
Basic column types are shown in another page.
Ion exchange plant design some basic principles you will not find here a complete plant design manual.
Bigger vessels with up to 4 0 m are sometimes built but the aspect ratio of the resin bed width height becomes unfavourable and very precise distribution and collection systems must be fitted to ensure an even flow of the water during service and.
The design of the vessels should give a maximum resin bed depth while limiting the pressure drop across the resin bed to 1 bar.